Customization: | Available |
---|---|
Type: | Fiber Amplifier |
Wiring Devices: | Integrated Wiring |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
NO. | Parameter | Min | Typical | Max | Unit | Comment |
1. | Operating temperature | -5 | - | 55 | .C | Need to add heat dissipation |
2. | Storage temperature | -40 | - | 85 | .C | - |
3. | Operating relative humidity | 5 | - | 85 | % | No condensation |
4. | Storage relative humidity | 5 | - | 95 | % | - |
Parameter | Min | Typ | Max | Unit | Comment |
Center wavelength | 1540 | 1550 | 1565 | nm | |
Input optical power range | -10 | 0 | 10 | dBm | |
Output optical power range | 17 | 34.7 | 37 | dBm | @Output up to 5W |
Noise figure | - | 5 | 5.5 | dB | @Output=34.7dBm |
Output fiber type | SMF28E or equivalent fiber, φ3 or φ2 yellow fiber optic cable | ||||
Output fiber length | 45 | 50 | 55 | cm | |
Output fiber optic connector type | FC/APC | - | |||
Working mode | APC(default)/ACC | ||||
Return Loss | 45 | - | - | dB | |
Output power stability | ±0.1 | dB | |||
Power reporting accuracy | ±0.5 | dB | |||
Input and output isolation | - | - | dB | ||
Polarization-dependent gain | 0.3 | dB | |||
Polarization mode dispersion | - | - | 0.5 | ps | |
Input optical power alarm threshold | -13 | dBm | When the input optical power is ≤-13dBm, the alarm is issued and the pump laser is turned off | ||
Output optical power alarm threshold | 16 | dBm | This alarm is generated when the output optical power is less than 16dBm | ||
980 Pump laser alarm threshold (built-in TEC) | 20~30 | ºC | When the pump laser temperature exceeds the range of 20~30ºC, an alarm is issued and the pump laser is turned off | ||
940 Pump laser alarm threshold (without TEC) | -15~85 | ºC | When the pump laser temperature exceeds the range of -15~85ºC, an alarm is issued and the pump laser is turned off | ||
Module temperature alarm threshold | -15~65 | ºC | When the pump laser temperature exceeds the range of -15~65ºC, an alarm is issued and the pump laser is turned off | ||
Optical port | - | - | - | - | 2(1 input + 1 output) |
The APC output power can be ranged | 17 | - | 37 | dBm | Set the accuracy to 0.1dB |
ACC current control accuracy | - | - | 5 | % |
NO. | Parameter | Min | Typical | Max | Unit |
1 | Supply voltage | 12 | 12 | 14 | V |
2 | Supply current | - | - | 6 | A |
3 | Power consumption | - | 60 | - | W |