Customization: | Available |
---|---|
Application: | Communication, Sensor |
Type: | Pm Fiber |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Number | Parameters | Min | Typical | Max | Unit | Remarks |
1. | Operating temperature | -5 | - | 55 | .C | |
2. | Storage temperature | -40 | - | 85 | .C | |
3. | Operating relative humidity | 5 | - | 85 | % | |
4. | Storage relative humidity | 5 | - | 95 | % |
Num ber | Parameters | Min | Typical | Max | Unit | Remarks |
1. | Wavelength | - | 1550.12 | - | nm | - |
2. | Bandwidth | 1549.92 | - | 1550.32 | nm | C34@100G filtering |
3. | Channels | - | 1 | - | - | - |
4. | Input average optical power | -24 | -19 | -14 | dBm | - |
5. | Average optical power output | -10 | -2.5 | 5 | dBm | - |
6. | ACC output power | -10 | - | 10 | dBm | @ACCWorking mode |
7. | ACC mode current control accuracy | - | 0.5 | - | mA | @ACCWorking mode |
8. | APC output power | -10 | - | 10 | dBm | @APCWorking mode |
9. | Pulse width | 100 | - | 300 | ns | - |
10. | Repetition rate | 1k | - | 2k | Hz | - |
11. | noise | - | 5.5 | 6 | dB | @Gain>17dB |
12. | Return loss | 45 | - | - | dB | - |
13. | No light report | -60 | dBm | |||
14. | Output power stability | - | - | ±0.1 | dB | - |
15. | Power reporting accuracy | - | - | ±0.5 | dB | - |
16. | Output power control accuracy | - | - | ±0.5 | dB | - |
17. | Input and output isolation | 30 | - | - | dB | - |
18. | Polarization dependent gain | - | - | 0.3 | dB | - |
19. | Polarization film dispersion | - | - | 0.5 | ps | - |
20. |
Input optical power alarm |
- |
-34 |
- |
dBm |
1. The default input does not alarm, and the pump is off 2. Range: -34~ 4dBm, Upward hysteresis 1dB, Prompt no power @<-34dBm |
21. |
Output optical power alarm |
- |
-10 |
- |
dBm |
The default input does not alarm, and the pump is off2, Range: -10 ~ +16dBm, Upward hysteresis 1dB, Prompt no power @ <-11dBm |
22. | Module low temperature alarm | - | -25 | - | ºC | The alarm shuts down the pump |
23. | Module overtemperature alarm | - | 65 | - | ºC | The alarm shuts down the pump |
24. | Pump low temperature alarm | - | 20 | - | ºC | The alarm shuts down the pump |
25. | Pump high temperature alarm | - | 30 | - | ºC | The alarm shuts down the pump |
26. | Input and output optical fiber length | 95 | 100 | 105 | cm | Connector length included |
27. | Input and output optical fibers Type | 900um Loose White SMF-28e | ||||
28. | Connectors Type | FC/APC | ||||
29. | Working mode | ACC | ||||
30. | port | Quantity 4:In1,In2,Out1,Out2 |