Customization: | Available |
---|---|
Type: | Fiber Amplifier |
Wiring Devices: | Integrated Wiring |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
NO. | Parameter | Min | Symbol | Max | Unit | Comment |
1. | Operating temperature | -5 | 55 | ºC | ||
2. | Storage temperature | -40 |
85 |
ºC | ||
3. | Operating relative humidity | 5 | 85 | % | No condensation at 40 °C | |
4. | Storage relative humidity | 5 | 95 | % |
Parameter | Min | Symbol | Max | Unit | Comment |
Center wavelength | 1540 | 1550 | 1560 | nm | |
Input optical power range | -5 | - | 10 | dBm | |
Output optical power range | 15 | 33 | 35 | dBm | |
Noise figure | - | 5 | 5.5 | dB | @Output=34.7dBm |
Output fiber type | SMF-28e (YOFC) | - | SMF28e ,900um | ||
Output fiber length | 95 | 100 | 105 | cm | (With connector) |
Output fiber optic connector type | FC/APC | - | |||
Working mode | APC(default)/ACC | ||||
Return Loss | 45 | - | - | dB | |
Output power stability | ±0.1 | dB | |||
Power reporting accuracy | ±0.5 | dB | |||
Input and output isolation | 30 | dB | |||
Polarization-dependent gain | - | - | 0.5 | ps | |
Input optical power alarm threshold | -13 | dBm | It can be set, the range is -13~9dBm, the upward hysteresis is 1dB, and less than -16dBm is reported without light | ||
Output optical power alarm threshold | 10 | dBm | The range can be set 10~34dBm, the upward hysteresis is 1dB, and less than 7dBm is reported without light | ||
Close the pump threshold | -14 | dBm | Configurable, range -14~9dBm, upward hysteresis 1dB | ||
Default temperature alarm threshold | -5 | 70 | 70 | ºC | Settable, range -5~+70 °C, upward hysteresis 1 °C |
Optical port | - | - | - | - | 2(1 Input 1 output) |
The APC output power can be ranged | 15 | - | 35 | dBm | |
ACC current control accuracy | - | - | 5 | % |